I. Cartridge, see fold-out page III, Fig [13].
Assemble in reverse order. When installing the cartridge,
ensure that the seals are correctly seated. Replace screw
coupling and tighten.
II. Headpart, see fold-out page III, Fig. [14].
Assemble in reverse order. Note the installation position of the
stop.
III. Diverter, see fold-out page III Fig. [15].
Assemble in reverse order.
IV. Mousseur (48 196), see fold-out page I.
Assemble in reverse order.
V. Solenoid valve (42 390), see fold-out page I.
Assemble in reverse order.
VI. Non-return valve (08 565), see fold-out page I.
Assemble in reverse order.
Service
Note the Fault / Cause / Remedy table for information on
eliminating problems.
If EE flashes or the problem cannot be rectified, interrupt the
power supply and consult a specialist installer or contact the
GROHE Service Hotline via email under TechnicalSupport-
Replacement parts
See fold-out page I (* = special accessories).
Care
For directions on the care of this fitting, please refer to the
accompanying Care Instructions.
Environment and recycling
Used filter cartridges can be disposed of hazard-free in
domestic waste.
Fault Cause Remedy
Water not flowing Water supply interrupted
Solenoid valve defective
Plug-in connector of solenoid valve
without contact
- Open shut-off valves
- Replace solenoid valve
- Attach plug-in connector
Filtered water not
flowing
Water supply interrupted - Establish water supply to fitting
Filtered water is
interrupted, E2
flashes in the display
Safety shut-off of solenoid valve for
running time of over 4 minutes
- Close handle and open it again.
No filtered water, E3
in the display
No connection between fitting and
cooler/carbonator
Cable or connector faulty
- Connect plug-in connector
- Contact GROHE Service
No filtered water,
Blue
®
handle flashes
red, E4 in the display
Fitting and control unit not synchronized - Synchronise with one another, see section
Installation
No filtered water,
Blue
®
handle flashes
red, E6 in the display
Values range does not concur - Synchronise with one another, see section
Installation
Blue
®
handle flashes
orange, E7, E8 in the
display
Filter capacity exceeded - Change filter cartridge immediately
Indicator lamps
do not flash/flash
continuously
Control not recognised - With mains plug connected, disconnect plug-in
connector, wait 30 seconds and reconnect
Display in handle
does not illuminate
or illuminates
continuously
No connection between fitting
and control unit
- Synchronise with one another, see section
Installation